The Status and Parameter Display shows controller information and advanced settings. The default display is actual system pressure, shown as “60P” where “60” is the pressure value and “P” stands for PSI. You can select a pressure range in the Advanced Settings menu.
Use the Up and Down buttons to change the system pressure setpoint, and to navigate the Advanced Settings menu.
For a pressure other than 60 PSI: With the status display showing system pressure, press the UP or DOWN button to increase or decrease the pressure setpoint. If the active pressure setpoint is Setpoint 1, the display blinks “SP1” for three seconds, then shows the new value. If Setpoint 2 is active, the display blinks “SP2,” then shows the new value.
NOTE: When setting the system pressure setpoint, be sure to adjust the tank air pressure accordingly.